Do I Need To Shear Wall For Siding

I m set in my ways.
Do i need to shear wall for siding. A wall with doors and windows may require less squares of material to cover than a wall with no doors. The. Framing or one bay for 24 inch o c. 2 on the ends if there is a double stud for a hold down you can either stitch nail the two studs together 3 o c.
It s best to stagger the joints in each successive course to avoid noticeable patterns. The building envelope to do their jobs without being assaulted by wind precipitation and uv rays. You can go over preexisting siding as long as it is flat and in good shape. Exterior cladding or siding is your first line of defense against weather elements and its job is to allow interior control layers ie.
I want to frame sheathe a wall with cdx install felt and windows and doors and then install siding or preferably sidewall shingles. And stagger nails 6 o c. Is t 111 siding considered structural. Remember your shear wall may be the only thing between safety and catastrophe and it needs to be built perfectly.
Their job is to keep the inside in and the outside out. Remove and repair any damage portions and use a weather restrictive barrier between our product and the preexisting siding. Finally as for shear stregnth i can rip a hardi panel w my bare hands. There is an important relationship between the proportions of a typical wood shearwall.
For walls longer than 12 feet you ll need to butt additional lengths of siding together. Even if you never have a storm or an earthquake or otherwise any need for the shear stregnth of your exterior walls somewhere sometime someone s gonna throw a baseball at your garage and it s gonna punch a nice hole in your nice hardi siding. Need to combine with top floor hold down requirements based on capacity of first shear wall panel does not include dead load. The walls of your home are an environmental separator.
On each stud this makes a total of 3 o c. Right but to make it into shear i d have to nail the sh t out of it with big headed nails rather than the slight head spirals that i use with t1 11. The taller it is the more of a tendency it has to turn over when a lateral force is applied. For example an average door is 3ft wide by 7ft.
Nailing on this edge or nail into the. Butt joints in adjacent courses should be spaced apart by at least two stud bays for 16 inch o c. This guide is available as a free download from the apa. You need increase the fastener length the thickness of the siding and make sure the fasteners go into the framing.